CPR PRODUCT FINDER
CONFill®, CONLink®, CONGuard® LSF CPR solutions
Communication cables
Application |
Reference |
Tensile Strength |
Elongation |
LOI |
MfR 150°C; 21,6 kg |
CPR Class indication (Dependent on construction) |
Comments |
|
[MPa]/ [psi] |
[%] |
% [O2] |
[g/10 min.] |
|
|
Data |
CONGuard® S 6610 SK LDD UV |
11/ 1600 |
160 |
35 |
5,5 |
Dca -s1,d1,a1 |
High speed, low drool, low shrinkage, good diameter control. Low water absorption. |
Data |
CONGuard® S 6615 LDD UV |
11/ 1600 |
170 |
39 |
5,5 |
Cca -s1,d1,a1 |
Low drool, high speed, good diameter control. |
Data |
CONGuard® S 6625 S LDD |
12,5/ 1810 |
180 |
36 |
6,5 |
Dca -s1,d1,a1 |
Easy processing ans low drool compound with good LOI. Designed for shotgun profiles. |
Data |
CONGuard® S 6640 S N |
12/ 1740 |
180 |
38 |
3,1 |
Cca -s1,d0,a1 |
Very good char forming compound. Fire alarm cable. |
Data |
CONGuard® S 6650 S LDD UV |
11/ 1600 |
170 |
47 |
3 |
B2ca -s1,d1,a1 |
High flame retardancy. Solid char. Long-term temperature 70°. |
Data |
CONGuard® S 8850 S LDD UV |
12,5/ 1810 |
160 |
48 |
2,5 |
B2ca -s1,d1,a1 |
High flame retardancy. Solid char. Very good crack resistance. Long-term temperature 90°C. |
Flexible cords |
CONGuard® S 6680 |
11/ 1600 |
200 |
32 |
4 |
Eca |
Highly flexible PVC replacement.Passes 30,000 cycle flex test. |
Optical fibre tight buffer |
CONGuard® I 6541 LDD TB |
12/ 1740 |
170 |
45 |
7 |
B2ca -s1,d1,a1 |
Very low shrinkage good adhesion and ovality . No die drool. For thin wall extrusion. |
Optical fibre sheathing |
CONGuard® S 6610 LDD UV |
11/ 1600 |
170 |
37 |
10 |
Dca -s1,d1,a1 |
High speed, low drool, low shrinkage, good diameter control +UV additive. |
Optical fibre sheathing |
CONGuard® S 6615 LDD UV |
11/ 1600 |
170 |
39 |
5,5 |
Cca -s1,d1,a1 |
High speed, low drool, low shrinkage, good diameter control +UV additive. |
Optical fibre sheathing |
CONGuard® S 6650 MAA LDD UV |
11/ 1600 |
140 |
48 |
2,5 |
B2ca -s1,d1,a1 |
Premium fire performance designed to meet B2 at loose tube constructions. Char forming. |
Optical fibre sheathing |
CONGuard® S 8541 LDD UV |
12/ 1740 |
170 |
43 |
7 |
Cca -s1,d1,a1 |
High fire performance designed to meet Cca at tight buffer constrcutions, very low shrinkage. |
LV Power cables
Application |
Reference |
Tensile Strength |
Elongation |
LOI |
MfR 150°C; 21,6 kg |
CPR Class indication (Dependent on construction) |
Comments |
|
|
[MPa]/[psi] |
[%] |
% [O2] |
[g/10 min.] |
|
|
Thermosetting insulation |
CONLink® I 4100 |
13/ 1885 |
250 |
34 |
6 |
D>ca-B2ca |
Ambient cure cross-linkable fire retardant insulation material. |
Fire integrety/House wiring |
CONFill® 640 |
|
|
45 |
|
D>ca-Cca |
Fire retardant bedding compound, less sticking on XLPE |
Fire integrety/House wiring |
CONFill® 5212 |
1/ 145 |
40 |
60 |
|
D>ca-B2ca |
Premium fire retardant bedding compound, less sticking on XLPE |
Fire integrety/House wiring |
CONFill® 5217 |
7/ 1015 |
100 |
75 |
|
D>ca-B2ca |
Premium fire retardant bedding compound, no sticking on XLPE. Strong char. |
Fire integrety/House wiring |
CONFill® 5375 |
|
|
70 |
|
D>ca-B2ca |
Premium fire retardant bedding compound |
Fire integrity/House wiring |
CONGuard® S 6545 N |
10,8/ 1566 |
150 |
43 |
3 |
B2>ca -s1,d0,a1 |
High flame retardancy with char promoter |
Fire integrity/House wiring |
CONGuard® S 6610 SK LDD UV |
11/ 1600 |
160 |
35 |
5,5 |
C>ca -s1,d1,a1 |
Good general purpose easy flow material. Low water absorption. |
Fire integrety/House wiring |
CONGuard® S 6625 S LDD |
12,5/ 1810 |
180 |
36 |
6,5 |
D>ca -s1,d1,a1 |
Easy flow HM4 meeting LTS1-4. Good tear resistance. |
Fire integrity/House wiring |
CONGuard® S 6640 S N |
12/ 1740 |
180 |
38 |
3,1 |
C>ca -s1,d0,a1 |
Very good char forming compound with very good processing characteristic. |
Fire integrity/House wiring |
CONGuard® S 6642 S LDD UV |
11/ 1600 |
180 |
36 |
3,1 |
C>ca -s1,d0,a1 |
Char forming compound for bedding free installation cables |
Fire integrity/House wiring |
CONGuard® S 6650 S LDD UV |
11/ 1600 |
170 |
47 |
3 |
C>ca -s1,d1,a1 |
rsuchs mal. |
Fire integrity/House wiring |
CONGuard® S 8541 S LDD |
12/ 1740 |
170 |
43 |
5 |
C>ca -s1,d1,a1 |
Good general purpose easy flow material meeting LTS1-4.Good stress crack resistance. |
Fire integrity/House wiring |
CONGuard® S 8865 S LDD UV |
12/ 1740 |
145 |
48 |
3 |
B>ca -s1,d0,a1 |
High flame retardancy with good char. Long-term temperature 90°C. |
Class |
Description |
B2ca |
Bunched cable flame test without backboard – flame spread <1.5 meters. |
Cca |
Bunched cable flame test without backboard – flame spread <2.0 meters. |
Dca |
Bunched cable flame test – no flame spread limit – total heat release at 20 minutes < 70 MJ. |
Eca |
Single cable flame test. |
Fca |
No performance determined. |
Sub categories |
s |
Smoke generation.S1 mandatory for LSF cables |
d |
Number of droplets during burning |
a |
Acidity |